Przejdź do treści

Controllers

Controllers

Vibratory feeders are powered by controllers dedicated to operate with electromagnetic devices.
We present in our offer a well proven proprietary products subjected to rigorous testing.
Well diversified offer of controllers for vibratory feeders facilitates compliance with our clients’ requirements offering a vast variety of functions:

  • Stepless element transport speed control,
  • Smooth start and stop of feeder operation (the so-called ramp),
  • Possibility to use external analogous signal to control device’s operation,
  • 24V DC blocking connector,
  • Input signal frequency control with frequency converter,
  • Feeder system operation control using external sensors,
  • Possibility to control operation with pneumatic electrovalve supporting vibratory feeder action,
  • Continuous regulation of feeder vibration amplitude using an accelerometer in the feedback system,
  • Possibility to use only one controller for 2 or even 3 vibrators..
KEY:
*Sensors – not sold together with controllers. The table shows controller’s technical capabilities.
* Accelerometer – not sold together with controllers. The table shows controller’s technical capabilities.
+ (Potentiometer in the table) – factory fitted on controller’s front panel
ZEW. 10kΩ (Potentiometer in the table) – possibility to fit an external industrial 10kΩ potentiometer to the controller internal connection.
Soft/fast ramp – increase of the start or stop signal to avoid any surge associated with sudden drive unit stoppage. Control in three time intervals separated steplessly from each other (every 0-4s)
*3 channel – controller operating 3 vibratory feeders:
Vibratory hopper (6A) – Cylindrical feeder (8A) – Linear feeder (6A)
MCP12/MCP03

Manufacturer: M.P.Elettronica

Old look of the controller
  • Modular 3-channel controller operating a set of vibratory feeders.
  • Management of the feeder set operation through a digital display device e.g.:
    Vibratory hopper (to 6A) – Cylindrical feeder (to 8A) – Linear feeder (to 6A);
  • Two-stage amplitude control for cylindrical feeder (two-speed controller);
  • Blocking connector (24VDC) – logic interruption of feeder operation;
  • Connectors controlling feeders operation stoppage (following sensors operation):
    a) Vibratory hopper,
    b) Linear feeder (buffer with a possibility to double number of sensors – min/max buffer);
  • Assembly connector of pneumatic electrovalve;
  • Alert lamp (24VDC) reporting element tie-up;
  • Advanced controller logic and programme options;
  • Device in casing providing IP54 protection level.
FQ2N-DIG

Manufacturer: M.P.Elettronica

  • Digital control vibratory feeder supply;
  • Amplitude adjustment (feeder output);
  • Amplitude sensor feating connector/accelerometer/for automatic amplitude adjustment in case of load change (optional);
  • Connectors controlling feeder operation switch off (after sensor operation):
    a) Vibratory hopper,
    b) Linear feeder (buffer overstacking)
  • Vibration frequency adjustment;
  • External signal analogous control;
    (two industrial standards are available: 0-10V or 0-20mA)
  • Blocking connector (24VDC) – logic interruption of feeder operation
  • Device in casing providing IP55 protection level.
MFS 168

Manufacturer: Reo Reovib

  • Advanced controller adjusting vibratory feeder operation;
  • Digital control vibratory feeder supply
  • Assembly connector of filling up sensor (or overstacking sensor) controlling feeder switching off;
  • Amplitude adjustment (feeder output)
  • Amplitude sensor feating connector / accelerometer/for automatic amplitude adjustment in case of load change (optional);
  • Vibration frequency adjustment;
  • External signal analogous control;
    (two industrial standards are available: 0-10V or 0-20mA)
  • Two stage aplitude adjustment /two speed controller/;
  • Blocking connector (24VDC) – logic interruption of feeder operation
  • Device in casing providing IP54 protection level.
SMART IP20

Manufacturer: Reo Reovib

  • Vibratory feeder supply with a possibility to select the control method:
    a) Potentiometer adjusted output
    b) External signal analogous control;
  •     (two industrial standards are available: 0-10V or 0-20mA)
  • Blocking connector (24VDC) – logic interruption of feeder operation;
  • Potentiometric limiter of output voltage (min. and max. feeder output);
  • Device in casing providing IP20 protection level/to be fitted inside a cabinet;
  • Vibratory feeder supply with potentiometer amplitude adjustment
    (feeder output)
  • External signal analogous control
    (two industrial standards are available: 0-10V or 0-20mA)
  • Blocking connector (24VDC) – logic interruption of feeder operation;
  • Device in casing providing IP20 protection level.
SMART IP54

Manufacturer: Reo Reovib

  • Vibratory feeder supply with a possibility to select the control method:
    a) Potentiometer adjusted output
    b) External signal analogous control;
  •     (two industrial standards are available: 0-10V or 0-20mA)
  • Blocking connector (24VDC) – logic interruption of feeder operation;
  • Potentiometric limiter of output voltage (min. and max. feeder output);
  • Device in casing providing IP20 protection level/to be fitted inside a cabinet;
  • Vibratory feeder supply with potentiometer amplitude adjustment
    (feeder output)
  • External signal analogous control
    (two industrial standards are available: 0-10V or 0-20mA)
  • Blocking connector (24VDC) – logic interruption of feeder operation;
  • Device in casing providing IP54 protection level.
RG-02/T

Manufacturer: S+R Electronic

  • Vibratory feeder supply with potentiometric amplitude adjustment
    (feeder output)
  • Four start and stop speed adjustment steps;
  • Blocking connector (24VDC) – logic interruption of feeder operation;
  • Sensor connectors with control logic;
  • Device in casing providing IP54 protection level.
RG-01/RA

Manufacturer: S+R Electronic

  • Vibratory feeder supply with potentiometric amplitude adjustment
    (feeder output)
  • Four start and stop speed adjustment steps;
  • Blocking connector (24VDC) – logic interruption of feeder operation;
  • Device in casing providing IP54 protection level.